Sign In | Join Free | My entremaqueros.com
China Shanghai Glomro Industrial Co., Ltd. logo
Shanghai Glomro Industrial Co., Ltd.
Global MRO Solutions.
Verified Supplier

6 Years

Home > Laboratory Testing Equipment >

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers.

Shanghai Glomro Industrial Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers.

Brand Name : BAXIT

Model Number : BXT-AAS4HS

Place of Origin : china

MOQ : 1

Price : USD 11030-13510/unit

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 1000units

Delivery Time : 3-5working days

Packaging Details : wooden box

Classification : Flame Graphite Integrated Machine (4Lamp Positions)

Model : BXT-AAS4HS

Detector : Hamamatsu Photomultiplier Tube from Japan

wavelength range : (185-900)nm

Wavelength indication error : ≤±0.1nm

Wavelength repeatability : ≤±0.025nm

Baseline drift : 0.001ABS/30min(Static) 0.003ABS/15min(Dynamic)

Light source system : Rotary turret-type fully automatic switching lamp holder

Element lamp Lighting mode : 400Hz, 1/4 duty cycle pulse is on

Monochromator : Czerny-Turner Enhanced type

Grating line density : 1800

Spectral bandwidth : 0nm、0.1nm、0.2nm、0.4nm、1.0nm、2.0nm Multi-gear automatic switching

Flame atomization system : Standard equipment

Burner : 0.5mmx100mmAll-titanium combustion head

Sprayer : Metal sleeve high-efficiency glass spray nozzle

Atomization chamber : Corrosion-resistant all-plastic atomization chamber

Repetition : RSD≤0.7%

Detection limit : 1.5pg

Safety protection : Pressure system failure protection, cooling system failure protection, real-time power monitoring

Sample size : 1-99

Result output : Multi-format data storage and print output

Communication interface : RS232, USB expansion interface

Host machine size : 1000x400x470mm

Graphite Furnace Atomic Absorption System : Standard configuration

Precision : ≤3%

Heating temperature range : Room temperature-3000℃

Heating speed : 2000 degrees per second

Temperature control accuracy : 1%

Heating conditions setting : 11 step, ramp temperature rise, stepwise temperature rise, maximum power temperature rise, temperature rise monitoring opposite-side system

Background correction (deuterium lamp) : When using 1ABS, the value should be ≥ 60 times.

Contact Now

Atomic Absorption Spectrophotometer

Atomic absorption spectrophotometer can be widely applied in various industries such

as geology, metallurgy, medicine, chemical engineering, petroleum, agriculture, environmental

protection and commodity inspection. The application of it for the analysis of trace and ultra-trace

elements has gradually shifted from inorganic chemistry to organic chemistry in recent years.

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers.

Working principle

The characteristic spectral radiation of the element to be measured is emitted by the light

source and absorbed by the ground-state atoms of the element to be measured in the vapor

of the sample produced by the atomizer such as a flame or graphite furnace. The content of

the element to be measured is determined by measuring the amount of the characteristic

spectral radiation absorbed.

Classification Flame type
(4,6,8Lamp Positions)
Flame Graphite Integrated Machine
(4,6Lamp Positions)
Fully automatic flame graphite integrated machine
(8Lamp Positions)
Model BXT-AAS4H
BXT-AAS6H
BXT-AAS8H
BXT-AAS4HS
BXT-AAS6HS
BXT-AAS8HS-P
Detector Hamamatsu Photomultiplier Tube from Japan
wavelength range (190-900)nm (185-900)nm
Wavelength indication error ≤±0.1nm
Wavelength repeatability ≤±0.025nm
Baseline drift 0.001ABS/30min(Static) 0.003ABS/15min(Dynamic)
Light source system Rotary turret-type fully automatic switching lamp holder
Element lamp
Lighting mode
400Hz, 1/4 duty cycle pulse is on
Monochromator Czerny-Turner Enhanced type
Grating line density 1800
Spectral bandwidth 0nm,0.1nm,0.2nm,0.4nm,1.0nm,2.0nm Multi-gear automatic switching
Atomizer Flame atomizer
Flame atomization system Standard equipment
Burner 0.5mmx100mmAll-titanium combustion head
Sprayer Metal sleeve high-efficiency glass spray nozzle
Atomization chamber Corrosion-resistant all-plastic atomization chamber
Repetition RSD≤0.7%
Detection limit (Cu)<0.006ug/ml
Safety protection It has multiple safety protection functions, including alarm for acetylene leakage and system shutdown.
Graphite Furnace Atomic Absorption System No Standard configuration
Detection limit No 1.5pg
Precision No ≤3%
Heating temperature range No Room temperature-3000℃
Heating speed No 2000 degrees per second
Temperature control accuracy No 1%
Heating conditions setting No 11 step, ramp temperature rise, stepwise temperature rise, maximum power temperature rise, temperature rise monitoring opposite-side system
Safety protection No Pressure system failure protection, cooling system failure protection, real-time power monitoring
Background correction (deuterium lamp) No When using 1ABS, the value should be ≥ 60 times.
Background correction No When using 1ABS, the value should be ≥ 60 times.
Automatic sample introduction system No 85 channels, automatic calibration curve configuration, automatic dilution function, high-precision injection
Sample size 1-99
Result output Multi-format data storage and print output
Communication interface RS232, USB expansion interface
Host machine size 1000x400x470mm 1030x430x400mm
Weight(kg) 75 120 130

Applicable scenarios

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers.

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers.

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers.

Product detail illustration

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers.

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers.

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers.


 Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers. Manufactures

Laboratory Flame Atomic Absorption Spectrophotometer with a wavelength range of 190 nanometers to 900 nanometers. Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shanghai Glomro Industrial Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)